Twisting bus wires

User avatar
Mr Bones
Posts: 695
Joined: Sun Oct 14, 2018 9:24 pm
Location: Canterbury Area
Contact:

Twisting bus wires

#1

Post by Mr Bones »

I've noticed a lot recently both on forums and on YouTube, that a lot of people no longer twist their bus wires. Is this a thing of the past or is it still recommended?
And the Lord said unto John “Come forth and receive eternal life”, but John came fifth and won a toaster!
User avatar
Steve M
Posts: 3606
Joined: Thu Oct 04, 2018 5:29 pm
Location: Rochester, Kent
Contact:

Re: Twisting bus wires

#2

Post by Steve M »

I’ve never done it and never had an issue.
Once twisted surely it becomes an issue to add extra droppers if needed?
"Not very stable, but incredibly versatile." ;)
User avatar
Mr Bones
Posts: 695
Joined: Sun Oct 14, 2018 9:24 pm
Location: Canterbury Area
Contact:

Re: Twisting bus wires

#3

Post by Mr Bones »

Actually Steve, you were one of the ones I noticed didn't do it. I've done in the past, but probably won't bother in the future.
And the Lord said unto John “Come forth and receive eternal life”, but John came fifth and won a toaster!
User avatar
Walkingthedog
Posts: 5059
Joined: Thu Oct 04, 2018 5:51 pm
Location: HAZLEMERE, BUCKS.
Contact:

Re: Twisting bus wires

#4

Post by Walkingthedog »

The bus is connected to the rails and they aren’t twisted.
Nurse, the screens!
User avatar
Rog (RJ)
Posts: 590
Joined: Thu Oct 04, 2018 5:49 pm
Location: South Nottingham
Contact:

Re: Twisting bus wires

#5

Post by Rog (RJ) »

If your bus wires are in close proximity to other wiring then twisting the bus wires can prevent interference between the bus wires and the other wires. Telephone cables, for example, have twist in the individual pairs of wires to prevent interference and overhearing.

Another recommendation is to keep the bus wires apart from each other and other wires.

The large current pulse that happens when solenoid point motors operate may be the most likely source of interference on a layout.
User avatar
Walkingthedog
Posts: 5059
Joined: Thu Oct 04, 2018 5:51 pm
Location: HAZLEMERE, BUCKS.
Contact:

Re: Twisting bus wires

#6

Post by Walkingthedog »

Telephone wire the type that was/is used for extensions, called 4 wire, had no twist, four individual wires.

I agree it is best to keep the bus away from other wires but that is not always easy.

Solenoid point motors are usually very close to the track which is in itself just an extension of the bus.

Some twist, some don’t, a matter of choice. I think it is better just to keep the two wires well apart, makes it a lot easier to attach droppers.
Nurse, the screens!
User avatar
Rog (RJ)
Posts: 590
Joined: Thu Oct 04, 2018 5:49 pm
Location: South Nottingham
Contact:

Re: Twisting bus wires

#7

Post by Rog (RJ) »

I'm not referring to internal cable but underground cable that used to contain up to about 800 pairs or more and ran for a number of miles. Even overhead open wire trunk lines would have twists in them.

I'm not saying that twists in bus wires are necessary but hopefully helping people to understand why twists might help.
User avatar
Walkingthedog
Posts: 5059
Joined: Thu Oct 04, 2018 5:51 pm
Location: HAZLEMERE, BUCKS.
Contact:

Re: Twisting bus wires

#8

Post by Walkingthedog »

With you now Rog. When I did my GPO apprenticeship (my dad was a cable jointer) cables were joined to a set plan, not colour to colour, so each pair of wires sort of spiralled along the lengths of cable but matched up at each end which of course were often many miles apart. So a blue wire could be joined to a red then that to brown then green and finally blue again in a simplified form.
Nurse, the screens!
User avatar
Brian
Posts: 2275
Joined: Thu Oct 04, 2018 3:49 pm
Location: SE Kent
Contact:

Re: Twisting bus wires

#9

Post by Brian »

Mr Bones wrote: Sun Aug 15, 2021 8:08 pm I've noticed a lot recently both on forums and on YouTube, that a lot of people no longer twist their bus wires. Is this a thing of the past or is it still recommended?
On long DCC Bus pair wire runs twisting will help overcome any induced interference. But on the average UK layout (up to around 18 feet long) keeping the two DCC bus wire about 50mm or more away form other wiring will ensure all is OK. However, all that said, there is no reason why around 8 to 10 twists per Mtr of the DCC bus wire wont hurt anyway! :D
Image << Click the Icon to go to my website
User avatar
teedoubleudee
Posts: 1116
Joined: Fri Oct 05, 2018 2:53 pm
Location: Downham Market
Contact:

Re: Twisting bus wires

#10

Post by teedoubleudee »

Walkingthedog wrote: Sun Aug 15, 2021 10:07 pm Telephone wire the type that was/is used for extensions, called 4 wire, had no twist, four individual wires.......................
Not true Brian, only last week I bought a couple of meters of telephone wire from Bitsbox. I use it a lot in my electronic projects. I stripped it only yesterday.

It had Orange/White twisted with White/Orange and Blue/White twisted with White/Blue. then the two twisted pairs were loosley twisted with each other all in a plastic white sheaf.
Most people are shocked when they find out how bad I am as an electrician
Post Reply

Who is online

Users browsing this forum: No registered users and 3 guests